二相步进电机驱动器ND2282

深圳市雷赛机电技术开发有限公司

2011年10月01日  来源:中国纺机网编辑部
 
工作电流设定
 
输出峰值电流
输出均值电流
SW6
SW7
SW8
SW9
0.45A
0.32A
off
off
off
off
0.63A
0.45A
off
off
off
on
1.41A
1.00A
off
off
on
off
1.88A
1.34A
off
off
on
on
2.33A
1.66A
off
on
off
off
2.85A
2.04A
off
on
off
on
3.23A
2.31A
off
on
on
off
3.75A
2.68A
off
on
on
on
4.26A
3.04A
on
off
off
off
4.65A
3.32A
on
off
off
on
5.18A
3.70A
on
off
on
off
5.55A
3.96A
on
off
on
on
6.15A
4.39A
on
on
off
off
6.60A
4.71A
on
on
off
on
7.20A
5.14A
on
on
on
off
7.80A
5.57A
on
on
on
on
 
微步细分设定
 
步数/转
SW1
SW2
SW3
SW4
400
on
on
on
on
500
off
on
on
on
600
on
off
on
on
800
off
off
on
on
1000
on
on
off
on
1200
off
on
off
on
1600
on
off
off
on
2000
off
off
off
on
2400
on
on
on
off
3200
off
on
on
off
4000
on
off
on
off
5000
off
off
on
off
6000
on
on
off
off
6400
off
on
off
off
8000
on
off
off
off
10000
off
off
off
off
 
 
接口信号描述
 
名称
功能
PUL+(+5V)
脉冲控制信号:脉冲上升沿有效;PUL-高电平时4-5V,低电平时0-0.5V。为了可靠响应脉冲信号,脉冲宽度应大于1.6μs。如采用+12V或+24V时需串电阻。
PUL-(PUL)
DIR+(+5V)
方向信号:高/低电平信号,为保证电机可靠换向,方向信号应先于脉冲信号至少 5μs建立。电机的初始运行方向与电机的接线有关,互换任一相绕组(如A+、A-交换)可以改变电机初始运行的方向,DIR-高电平时4~5V,低电平时0~0.5V。
DIR-(DIR)
ENA+(+5V)
使能信号:此输入信号用于使能或禁止。ENA+ 接+5V,ENA-接低电平(或内部光耦导通)时,驱动器将切断电机各相电流使电机处于自由状态,此时步进脉冲不被响应。当不需此功能时,使能信号端悬空即可。
ENA-(ENA)
FAULT+
故障信号OC输出:低电平故障,高电平正常,建议用1K上拉电阻接外部+5V。注意:FAULT+/FAULT-端与电源GND不共地。
 