五、CHV变频器系列
变频器型号 |
输入电压 |
额定输出功率(kW) |
额定输入电流(A) |
额定输出电流(A) |
适配电机 |
机型 |
CHV100-0R |
三相220V 范围: -15%~+15% |
0.75 |
5.0 |
4.5 |
0.75 |
C |
CHV100-1R |
1.5 |
7.7 |
7 |
1.5 |
C |
|
CHV100-2R |
2.2 |
11.0 |
10 |
2.2 |
C |
|
CHV100 |
3.7 |
17.0 |
16 |
3.7 |
C |
|
CHV100-5R |
5.5 |
21.0 |
20 |
5.5 |
C |
|
CHV100-7R |
7.5 |
31.0 |
30 |
7.5 |
D |
|
CHV100 |
11.0 |
43.0 |
42 |
11.0 |
E |
|
CHV100 |
15.0 |
56.0 |
55 |
15.0 |
E |
|
CHV100 |
18.5 |
71.0 |
70 |
18.5 |
E |
|
CHV100 |
22.0 |
81.0 |
80 |
22.0 |
F |
|
CHV100 |
30.0 |
112.0 |
110 |
30.0 |
F |
|
CHV100 |
37.0 |
132.0 |
130 |
37.0 |
F |
|
CHV100 |
45.0 |
163.0 |
160 |
45.0 |
G |
|
变频器型号 |
输入电压 |
额定输出功率(kW) |
额定输入电流(A) |
额定输出电流(A) |
适配电机 |
机型 |
CHV100-1R |
三相380V 范围: -15%~+15% |
1.5 |
5 |
3.7 |
1.5 |
C |
CHV100-2R |
2.2 |
5.8 |
5.0 |
2.2 |
C |
|
CHV100 |
3.7 |
10.0 |
9.0 |
3.7 |
C |
|
CHV100-5R |
5.5 |
15.0 |
13.0 |
5.5 |
C |
|
CHV100-7R |
7.5 |
20.0 |
17.0 |
7.5 |
D |
|
CHV100 |
11.0 |
26.0 |
25.0 |
11.0 |
D |
|
CHV100 |
15.0 |
35.0 |
32.0 |
15.0 |
D |
|
CHV100 |
18.5 |
38.0 |
37.0 |
18.5 |
E |
|
CHV100 |
22.0 |
46.0 |
45.0 |
22.0 |
E |
|
CHV100 |
30.0 |
62.0 |
60.0 |
30.0 |
E |
|
CHV100 |
37.0 |
76.0 |
75.0 |
37.0 |
F |
|
CHV100 |
45.0 |
90.0 |
90.0 |
45.0 |
F |
|
CHV100 |
55.0 |
105.0 |
110.0 |
55.0 |
F |
|
CHV100 |
75.0 |
140.0 |
150.0 |
75.0 |
G |
|
CHV100 |
90.0 |
160.0 |
176.0 |
90.0 |
G |
|
CHV100 |
110.0 |
210.0 |
210.0 |
110.0 |
G |
|
CHV100 |
132.0 |
240.0 |
250.0 |
132.0 |
H |
|
CHV100 |
160.0 |
290.0 |
300.0 |
160.0 |
H |
|
CHV100 |
185.0 |
330.0 |
340.0 |
185.0 |
H |
|
CHV100 |
200.0 |
370.0 |
380.0 |
200.0 |
I |
|
CHV100 |
220.0 |
410.0 |
415.0 |
220.0 |
I |
|
CHV100 |
250.0 |
460.0 |
470.0 |
250.0 |
I |
|
CHV100 |
280.0 |
500.0 |
520.0 |
280.0 |
I |
|
CHV100 |
300.0 |
580.0 |
600.0 |
300.0 |
I |
|
CHV100 |
315.0 |
580.0 |
600.0 |
315.0 |
I |
|
CHV100 |
350.0 |
620.0 |
640.0 |
350.0 |
J |
|
CHV100-400P-4 |
400.0 |
670.0 |
690.0 |
400.0 |
J |
|
CHV100 |
400.0 |
670.0 |
690.0 |
400.0 |
J |
|
CHV100-500P-4 |
500.0 |
835.0 |
860.0 |
500.0 |
J |
|
CHV100 |
500.0 |
835.0 |
860.0 |
500.0 |
J |
|
CHV100-560P-4 |
560.0 |
920.0 |
950.0 |
560.0 |
J |
|
CHV100 |
560.0 |
920.0 |
950.0 |
560.0 |
J |
|
CHV100-630P-4 |
630.0 |
1050.0 |
1100.0 |
630.0 |
J |
|
CHV100 |
630.0 |
1050.0 |
1100.0 |
630.0 |
J |
|
CHV100-700P-4 |
700.0 |
1250.0 |
1300.0 |
700.0 |
J |
|
变频器型号 |
输入电压 |
额定输出功率(kW) |
额定输入电流(A) |
额定输出电流(A) |
适配电机 |
机型 |
CHV100 |
三相690V 范围: -15%~+15% |
22.0 |
35.0 |
28.0 |
22.0 |
E |
CHV100 |
30.0 |
40.0 |
35.0 |
30.0 |
E |
|
CHV100 |
37.0 |
47.0 |
45.0 |
30.0 |
F |
|
CHV100 |
45.0 |
52.0 |
52.0 |
45.0 |
F |
|
CHV100 |
55.0 |
65.0 |
63.0 |
55.0 |
F |
|
CHV100 |
75.0 |
85.0 |
86.0 |
75.0 |
G |
|
CHV100 |
90.0 |
95.0 |
98.0 |
90.0 |
G |
|
CHV100 |
110.0 |
118.0 |
121.0 |
110.0 |
G |
|
CHV100 |
132.0 |
145.0 |
150.0 |
132.0 |
G |
|
CHV100 |
160.0 |
165.0 |
175.0 |
160.0 |
H |
|
CHV100 |
185.0 |
190.0 |
198.0 |
185.0 |
H |
|
CHV100 |
200.0 |
210.0 |
218.0 |
200.0 |
H |
|
CHV100 |
220.0 |
230.0 |
240.0 |
220.0 |
I |
|
CHV100 |
250.0 |
255.0 |
270.0 |
250.0 |
I |
|
CHV100 |
300.0 |
305.0 |
320.0 |
300.0 |
I |
|
CHV100 |
315.0 |
334.0 |
350.0 |
315.0 |
I |
|
CHV100 |
350.0 |
360.0 |
380.0 |
350.0 |
I |
|
CHV100 |
375.0 |
370.0 |
390.0 |
350.0 |
J |
|
CHV100 |
400.0 |
411.0 |
430.0 |
400.0 |
J |
|
CHV100 |
500.0 |
518.0 |
540.0 |
500.0 |
J |
|
CHV100 |
560.0 |
578.0 |
600.0 |
560.0 |
J |
|
CHV100 |
630.0 |
655.0 |
680.0 |
630.0 |
J |
|
变频器型号 |
输入电压 |
额定输出功率(kW) |
额定输入电流(A) |
额定输出电流(A) |
适配电机 |
机型 |
CHV100 |
三相1140V 范围: -15%~+15% |
37.0 |
27.0 |
25.0 |
30.0 |
\ |
CHV100B |
37.0 |
27.0 |
25.0 |
30.0 |
\ |
|
CHV100 |
45.0 |
32.0 |
31.0 |
45.0 |
\ |
|
CHV100B |
45.0 |
32.0 |
31.0 |
45.0 |
\ |
|
CHV100 |
55.0 |
38.0 |
38.0 |
55.0 |
\ |
|
CHV100B |
55.0 |
38.0 |
38.0 |
55.0 |
\ |
|
CHV100 |
75.0 |
51.0 |
52.0 |
75.0 |
\ |
|
CHV100B |
75.0 |
51.0 |
52.0 |
75.0 |
\ |
|
CHV100 |
90.0 |
57.0 |
58.0 |
90.0 |
\ |
|
CHV100B |
90.0 |
57.0 |
58.0 |
90.0 |
\ |
|
CHV100 |
110.0 |
72.0 |
73.0 |
110.0 |
\ |
|
CHV100B |
110.0 |
72.0 |
73.0 |
110.0 |
\ |
|
CHV100 |
132.0 |
85.0 |
86.0 |
132.0 |
\ |
|
CHV100 |
160.0 |
102.0 |
104.0 |
160.0 |
\ |
|
CHV100 |
185.0 |
113.0 |
115.0 |
185.0 |
\ |
|
CHV100 |
200.0 |
130.0 |
132.0 |
200.0 |
\ |
|
CHV100 |
220.0 |
141.0 |
144.0 |
220.0 |
\ |
|
CHV100 |
250.0 |
158.0 |
162.0 |
250.0 |
\ |
|
CHV100 |
300.0 |
176.0 |
180.0 |
300.0 |
\ |
|
CHV100 |
315.0 |
203.0 |
208.0 |
315.0 |
\ |
|
CHV100 |
350.0 |
210.0 |
216.0 |
350.0 |
\ |
|
CHV100 |
375.0 |
220.0 |
225.0 |
350.0 |
\ |
|
CHV100 |
400.0 |
252.0 |
260.0 |
400.0 |
\ |
|
CHV100 |
500.0 |
317.0 |
325.0 |
500.0 |
\ |
|
CHV100 |
560.0 |
356.0 |
365.0 |
560.0 |
\ |
|
CHV100 |
630.0 |
390.0 |
400.0 |
630.0 |
\ |
六、可靠性设计
1、全系列独立风道设计
全系列独立风道
散热器安装方式为柜体内、柜体外可选,风扇更换方便,变频器维护简单
极大提高了变频器在纺织、印染、化纤、造纸、拉丝、水泥制造等行业不同的应用环境下长期运行的可靠性
2、宽电网电压设计
电网输入电压在-15%~15%,变频器可安全运行,用户无须其他处理
3、18.5KW~90KW变频器标准配备直流电抗器
提高输入侧功率因数
提高整机效率及热稳定
有效消除输入侧的高次谐波对变频器的影响,减少对外围的干扰
4、超强的保护功能
为用户提供多达20多种的故障保护功能,可实现从变频器到电机、到外围设备的全方位保护
提供故障自动复位功能,方便常规故障的自动排除
内置雷击过流保护装置,有效提高对于感应雷的自我保护功能
5、标准的制造平台
专业化流水生产线
严格的生产管理制度